Our Products

Ambient Air Quality Monitor

The EE-AQMS-01 is built at the component level to provide an organization with the instruments it needs to meet its measurement objectives. It monitors inside & outside temperature, barometric pressure, wind direction, wind speed and Air Quality Monitoring such as So2, No2, Co2, Co, & Particulate Matter (Pm1, Pm2.5 & Pm10). The versatility of this automated AAQMS is evidenced in your ability to add, remove, or substitute sensors or other peripherals as your data measurement and monitoring needs change.

Enquire Now

Higher efficient
Vacuum pump

Internal-SD card

External USB Drive

Solar Panel

  • Operating Temperature:

    409 to +150'F (40 to +65'c)
  • Non-operating Temperature:

    -40" to +158'F (-40 to +70'C)
  • Current Draw

    5 mA (average) at 4 to 6 VDC for ISS only. 10 mA average for both
    console and ISS Connectors, Sensor.
  • Modular RJ-11 Cable Type:

    4-conductor, 26 AWG Cable Length, Anemometer: 40' (12 m)
    (included); 240' (73 m) (maximum recommended)
  • Temperature Sensor: (PN Junction Silicon Diode.)

    Range: -40" to +150%F (-40 to +65'C) Sensor Accuracy: +0.5'F
    (+0.3'C) (typical)
  • Relative Humidity Sensor: (Film capacitor element)

    Range: 1 to 100% RH Accuracy: +2%
  • Barometric Pressure

    Range: 16.00" to 32.50" Hg, 410 to 820 mm Hg, 540 to 1100 hPa/mb
    Overall Accuracy: +0.03" Hg (+0.8 mm Hg, +1.0 hPa/mb)
  • Solar Radiation: (Pyranometer)

    Range: o to 1800 W/m2 Accuracy: +5% of full scale (Reference: Eppley
    PSP at 1000 W/m2)
  • Particles Sensor: Laser Dust Sensor(PM1.0 PM2.5, PM10)

    Concentration output range: 0- 1000ug/m3
  • CO (Electrochemical gas sensor)

    Range: 0-1000 ppm
  • 02 (Electrochemical gas sensor)

    Range: 0-25 %
  • NO2 (Electrochemical gas sensor)

    Range: 0-20 ppm
  • SO2 (Electrochemical gas sensor)

    0-20 ppm
  • Co2 (NDIR Sensor)

    0-5000 ppm
  • Housing Material: UV-resistant

    ABS, polypropylene Sensor Inputs
  • RF Filter

    RC low-pass filter on each signal line
  • Operating Temperature:

    409 to +150'F (40 to +65'c)
  • Non-operating Temperature:

    -40" to +158'F (-40 to +70'C)
  • Current Draw

    5 mA (average) at 4 to 6 VDC for ISS only. 10 mA average for both
    console and ISS Connectors, Sensor.
  • Modular RJ-11 Cable Type:

    4-conductor, 26 AWG Cable Length, Anemometer: 40' (12 m)
    (included); 240' (73 m) (maximum recommended)
  • Temperature Sensor: (PN Junction Silicon Diode.)

    Range: -40" to +150%F (-40 to +65'C) Sensor Accuracy: +0.5'F
    (+0.3'C) (typical)
  • Relative Humidity Sensor: (Film capacitor element)

    Range: 1 to 100% RH Accuracy: +2%